ACT108-600E
AC Thyristor power switch in a SOT54 plastic package with self-protective capabilities against low and high energy transients
Features and Benefits
- Exclusive negative gate triggering
- Full cycle AC conduction
- Remote gate separates the gate driver from the effects of the load current
- Very high noise immunity
- Safe clamping of low energy over-voltage transients
- Self-protective turn-on during high energy voltage transients
Applications
- Fan motor circuits
- Pump motor circuits
- Lower-power highly inductive, resistive and safety loads
Type Number | Symbol | Parameter | Conditions | Min | Typ/Nom | Max | Unit |
---|---|---|---|---|---|---|---|
ACT108-600E | VDRM | repetitive peak off-state voltage | 600 | V | |||
IT(RMS) | RMS on-state current | full sine wave; Tlead ≤ 71 °C | 0.8 | A | |||
ITSM | non-repetitive peak on-state current | full sine wave; Tj(init) = 25 °C; tp = 20 ms | 13 | A | |||
full sine wave; Tj(init) = 25 °C; tp = 16.7 ms | 14.3 | A | |||||
Tj | junction temperature | 125 | °C | ||||
VPP | peak pulse voltage | Tj = 25 °C; non-repetitive, off-state; ten pulses on each voltage polarity; 20s or more between successive pulses; | 2.5 | kV | |||
IGT | gate trigger current | VD = 12 V; IT = 100 mA; LD+ G-; Tj = 25 °C | 1 | 10 | mA | ||
VD = 12 V; IT = 100 mA; LD- G-; Tj = 25 °C | 1 | 10 | mA | ||||
IH | holding current | VD = 12 V; Tj = 25 °C | 25 | mA | |||
VT | on-state voltage | IT = 1.1 A; Tj = 25 °C | 1.3 | V | |||
VCL | clamping voltage | ICL = 0.1 mA; tp = 1 ms; Tj = 25 °C | 650 | V | |||
dVD/dt | rate of rise of off-state voltage | VDM = 402 V; Tj = 125 °C; (VDM = 67% of VDRM); exponential waveform; gate open circuit | 2000 | V/µs | |||
dIcom/dt | rate of change of commutating current | VD = 400 V; Tj = 125 °C; IT(RMS) = 0.8 A; dVcom/dt = 20 V/µs; (snubberless condition); gate open circuit | 0.5 | A/ms |